Stage lamp CE certification standard EN60598-2-17
Stage lamp CE certification standard EN60598-2-17
Stage lamp CE certification standard EN60598-2-17
Important technical changes:
a) New requirements for construction methods for LED luminaires
b) Photobiosafety requirements are expanded
c) More precise requirements for insulation between different types of circuits
d) Other general upgrades and improvements
Major changes to the license or have an impact listed in Annex R
Annex R gives the key requirements for retesting the product (ie the test/evaluation that the standard upgrade may need)
The main chapters involved are:
1) Cl.4.28: Solid-state controller for thermal sensing controllers. 4.28: Fixing of thermal sensing controllers
2) Cl.10.3: Contact current, protection of conductor current and electrocautery
3) Cl.12.5.2: Temperature rise test under abnormal conditions of the igniter marked tc+X
4) Cl.3.2.12: Ground mark
5) Cl.3.2.23, 4.24.2: Retinal blue light hazard
6) Cl.3.3.22, Cl.4.31: Inter-circuit insulation
7) Cl.4.32, Cl.10.2: Overvoltage protection device
8) Cl.8.2.1, Annex M: The basic insulation touch